<LOGO>
FM Transmitter Measurement Report
Created: 2023-09-01 05-21-22
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.20 MHz 5/5, 52 dBuV RTL
Pilot RDS Phase Difference
0.0 kHz 3.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
3 kHz 68 kHz 19120 0,1151
Modulation Power
Limit Measuring Tolerance
8,0 dBr 1,0 dBr
MIN AVE MAX % above 9,0 dBr
3,8 dBr 6,13 dBr 7,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RTL " F211 0 (No PTY) 1 0 1 2 --:--
RT
-
AF EON
95.3, 99.8, 100.4, 101.3, 103.6, 103.9, 104.0, 104.1, 104.2, 104.3, 105.0, 105.1, 106.0 MHz -
FM Scope Station: 104.20 MHz, signal: 5/5 (52 dBuV) Max at: 68 kHz MIN: 3 kHz % above 75 kHz: 0,1151 Acquired: 2023/09/01 5:20:19 Total samples: 19120 Equivalent time: 0:15:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 7,5 dBr MIN: 3,8 dBr AVE: 6,13 dBr % above 9,0 dBr: 0,0 Last value: 4,1 dBr (2023/09/01 5:20:17) Station: 104.20 MHz, signal: 5/5 (52 dBuV) 05:06 05:08 05:10 05:12 05:14 05:16 05:18 05:20 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality